Products > "led strips 5.2 v 25252525252525252527":1667Products found
WIT-COLOR 3312 / 3308 Power Supply DC5V

WIT-COLOR 3312 / 3308 Power Supply DC5V

Item Code: ACC-WIT-DC5V-1

WIT-COLOR 3312 / 3308 Power Supply DC5V Printer Compatibility: WIT-COLOR 3312 / 3308 Manufacturer: WIT-COLOR Doesn’t wear easily; it has a usage time of 3 years under normal conditions of use. Most damages are caused by burning, so please pay attention to the connection of the different cables  

Printer Spare Parts >>

$42.38 - 45.08/pc

Ships to United States

Details >>

ROLAND VersaCamm SP-540V Service Manual (Direct Download)

ROLAND VersaCamm SP-540V Service Manual (Direct Download)

Item Code: SER-MAN-ROL-SP-540V

Title: Roland VersaCAMM SP-540V Service Manual (Direct Download) Format: PDF Size: 19 MB Description: To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through this manual completely. Unauthorized copying or transferral of this manual, in whole or in part, is prohibited. The documentation and the product have been prepared and tested as much as possible. If you find any misprint or error, please inform us. Content Abstract: The manual consists of seven chapters.  CHAPTER 1 Structure & Spare Parts. CHAPTER 2 Electrical Section. CHAPTER 3 Replacement of Main Parts. CHAPTER 4 Adjustment. CHAPTER 5 Supplemental Information. CHAPTER 6 Troubleshooting. CHAPTER 7 Service Activities. Notice: 1. You can download the PDF when the payment is made. 2. If you can't find the document that you need, please just click "Ask a Question" Button above to leave us a message.

Roland Service Manual >>

$10.90/pc

Ships to United States

Details >>

ROLAND VersaCamm SP-300, SP-300V Service Manual (Direct Download)

ROLAND VersaCamm SP-300, SP-300V Service Manual (Direct Download)

Item Code: SER-MAN-ROL-SP-300V

  Title: Roland VersaCAMM SP-300, SP-300V Service Manual (Direct Download) Format: PDF Size: 8.55 MB Description: To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through this manual completely. Unauthorized copying or transferral of this manual, in whole or in part, is prohibited. The documentation and the product have been prepared and tested as much as possible. If you find any misprint or error, please inform us. Content Abstract: The manual consists of seven chapters.  CHAPTER 1 Structure & Spare Parts. CHAPTER 2 Electrical Section. CHAPTER 3 Replacement of Main Parts. CHAPTER 4 Adjustment. CHAPTER 5 Supplemental Information. CHAPTER 6 Troubleshooting. CHAPTER 7 Service Activities. Notice: 1. You can download the PDF when the payment is made. 2. If you can't find the document that you need, please just click "Ask a Question" Button above to leave us a message.  

Roland Service Manual >>

$10.90/pc

Ships to United States

Details >>

Roland SP-300 SP-300V Large Format Printer English Service Manual (Direct Download)

Roland SP-300 SP-300V Large Format Printer English Service Manual (Direct Download)

Item Code: SER-MAN-ROL-SP-300

  Title: Roland SP-300 SP-300V large format printer English Service Manual (Direct Download) Format: PDF Size: 7.1MB Description: To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through this manual completely. Unauthorized copying or transferral of this manual, in whole or in part, is prohibited. The documentation and the product have been prepared and tested as much as possible. If you find any misprint or error, please inform us. Content Abstract: The manual consists of seven chapters.  CHAPTER 1 Structure & Spare Parts. CHAPTER 2 Electrical Section. CHAPTER 3 Replacement of Main Parts. CHAPTER 4 Adjustment. CHAPTER 5 Supplemental Information. CHAPTER 6 Troubleshooting. CHAPTER 7 Service Activities. Notice: 1. You can download the PDF when the payment is made. 2. If you can't find the document that you need, please just click "Ask a Question" Button above to leave us a message.  

Roland Service Manual >>

$6.84/pc

Ships to United States

Details >>

Myjet 180Lpi Encoder Strip (4200mm x 15mm)

Myjet 180Lpi Encoder Strip (4200mm x 15mm)

Item Code: ACC-LFP-091

Myjet 180Lpi 4200mm x 15mm Encoder Strip Printer Compatibility: MyJet Printers. Manufacturer: Myjet The strip is 1.8*420cm, length of it can be custom-made. How to Select Encoder Strip

Printer Spare Parts >>

$7.80 - 9.18/pc

Ships to United States

Details >>

3.4" x 2.1" Round Corner Heay Duty Die Credit Card Cutter

3.4" x 2.1" Round Corner Heay Duty Die Credit Card Cutter

Item Code: CS-D-011

This kind of card cutter is easy and convenient to operate with beautiful looking and have no rough edges on the finished products. This paper card cutter is a special tool for cutting paper card. And the paper card is 200gsm or 250gsm. There are lots of types and specifications which can meet customers'demands. • Working Size: 3.4" x 2.1" (86 x 54mm) round corner  • Volume: 21.3" x 18.5" x 16.1" (54 x 47 x 41cm) Notes: The price quoted is based on the mini order quantity, and it will be add 10% additionally if your order is less than the MOQ.  

Photo and card cutter >>

$38.92 - 43.24/pc

Ships to United States

Details >>

S&A CW-5000DG Industrial Water Chiller for Single 80W or 100W Engraving Machine, 6L Tank capacity, 750W Cooling Capacity, AC 1P 110V, 60Hz

S&A CW-5000DG Industrial Water Chiller for Single 80W or 100W Engraving Machine, 6L Tank capacity, 750W Cooling Capacity, AC 1P 110V, 60Hz

Item Code: CW-5000DGTY

. Application: CW5000-water-chiller-cool-for-Picosecond-Lasers CW5000-water-chiller-cool-for-UV-laser-marking-machine CW5000-water-chiller-cool-for-Uv-solid-laser CW5000-water-chiller-for-cooling-700W1500W-UV-light-source CW5000-water-chiller-for-cooling-UV-LED-source Industrial-chiller-CW-5000-for-HF

Industry Water Chiller >>

$460.00 - 500.00/set

Ships to United States

Details >>

S&A CW-5000TG Industrial Water Chiller for Single 80W or 100W Engraving Machine, 6L Tank capacity, 750W Cooling Capacity, AC 1P 220-240V, 50Hz

S&A CW-5000TG Industrial Water Chiller for Single 80W or 100W Engraving Machine, 6L Tank capacity, 750W Cooling Capacity, AC 1P 220-240V, 50Hz

Item Code: CW-5000TGTY

Description CW-5000DG industrial water chillers have been popular for over 16 years with the annual output of 30,000 units.It is designed for cooling the one CO2 glass laser tube under 120W of the laser engraving and cutting machine. (Its emitting rate is higher than 60%.)  Cooling capacity is 800W. Have design patent Certificate, CE and RoHS Certificate. This Water Chiller has been sold largely to Europe, South America, Asia and other markets. Economic cooling equipment, easy to install and operate, compact and easily movable. Features: It is suitable for cooling the laser tube under 120W, and the temperature can be adjusted precisely. You can choose different models according to local voltage and frequency. It can extend the using life of laser tube and ensure the engraving effect better. With completed water flow and over high temperature alarm functions It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices. Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm; This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement. CW-5000 water chiller has unique low flow alarm protection function, which ensures the cooling water cycle working safely. Specific disconnection alarm securing protection. Enclosed water tanks, water used for a long time. Equipped with alarm output port, can quickly protect sensitive components. High cost performance, low failure rate. Multiple power specifications; CE approval; REACH approval; RoHS approval. Tips: Make sure the refrigerant is filled before running the chiller. Refrigerant is forbidden by express company, so we could not put it into the package.You can buy it locally and fill it out. If the compressor of this chiller has not been filled with refrigerant. Please make sure it has been filled correctly according to the Filling Requirements paper put in the accessories box before running the chiller. ONTOUR AND PARTS INTRODUCTION   Independent production of sheet metal User-friendly control panel The temperature controller offers high precision temperature control of ±0.3°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.   Easy-to-read water level indicator The water level indicator has 3 color areas - yellow, green and red. Yellow area - high water level. Green area - normal water level. Red area - low water level. Dust-proof filter Integrated with the grill of the side panels, easy mounting and removal. Ease of moving and water filling The firm handle can help move the water chillers easily. Ventilation Distance Application Chiller CW-5000 for 120W metal laser cutting machine Water chiller CW-5000 for acrylic co2 laser cutting machine Industrial chiller CW-5000 for laser cutter Air cooled chiller CW-5000 for co2 laser cutting & engraving machine Water cooled chiller CW-5000 for uv laser marking machine CW-5000 chiller for 3w-5w uv laser machine Refrigeration water chiller CW-5000 for laser marking machine Compressor water chiller CW-5000 for UV curing system printer Industrial water chiller CW-5000 for laser marker Certificate Warehouse Test System Installation Open the package to check if the machine is intact and all the necessary accessories are completed.   Open the injection port to feed cooling water. (Do not let the water spill over!)   Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of cooling water additive (anti-corrosion water aqua). Working in cold north area, it’s better to use noncorrosive antifreeze fluid. According to system conditions, please connect the water inlet and outlet pipe well.   Plug in power, turn on the power switch. (Do not start up without water in the water tank!)   (1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal. (2) After the first boot, you must immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set value, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start over the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently. Check the water level in the water tank.   The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage. Adjust parameters of temperature controller.   CW-5000/5200 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to page 15, “Operating status and parameters adjustment.” Cautions Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded!   Please make sure there is stable and normal voltage for the working chiller!   As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 210 ~ 240V (110V model is of 100 ~120V). If you do need a wider operating voltage range, customization is available for us. Unmatched power frequency can cause the chiller damage!   Please choose model of 50Hz or 60Hz according to actual circumstance. To protect the pump, it’s strictly forbidden to run the chiller without water in the storage water tank!   The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited! Please be sure that the air inlet and air outlet are in good ventilation!   There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet. The filter screen must be regularly cleaned!   It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller. Please pay attention to the effect of the condensate water!   With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm. Professional use only!   The appliance is not to be used by children or persons with reduced physical,sensory or mental capabilities, or lack of experience and knowledge,unless they have been given supervision or instruction,children being supervised not to play with the appliance! Troubleshooting Failure Failure Cause Approach Machine turned on but unelectrified Power cord is not plugged in place Check and ensure the power interface and the power plug is plugged in place and in good contact. Fuse burnt-out Pull out the fuse box from the power supply interface of the chiller, check the fuse, replace with spare fuse if necessary and check whether the power supply voltage is stable; Check and ensure the power interface and the power plug is plugged in place and in good contact. Flow Alarm (panel red light is on)use a water pipe directly connect to the water outlet and inlet but still without water flowing Water level in the storage water tank is too low Check the water level gauge display, add water until the level shown in the green area; And check whether water circulation pipe leaks. Flow Alarm occurs while running with other equipment (panel red light is on),but there is water flowing and no alarm when use a water pipe directly connected to the chiller water outlet and inlet. Water circulation pipes are blocked or a pipe bending deformation. Check water circulation pipe Ultra-high temperature alarm Blocked dust gauze, bad thermolysis Unpick and wash the dust gauze regularly Poor ventilation for air outlet and inlet To ensure a smooth ventilation for air outlet and inlet Voltage is extremely low or astable To improve the power supply circuit or use a voltage regulator Improper parameter settings on thermostat To reset controlling parameters or restore factory settings Switch the power frequently To ensure there is sufficient time for refrigeration (more than 5 minuets) Excessive heat load Reduce the heat load or use other model with larger cooling capacity Alarm for ultra-high room temperature The working ambient temperature is too high for the chiller To improve the ventilation to guarantee that the machine is running under 40℃. Serious problem of condensate water Water temperature is much lower than ambient temperature, with high humidity Increase water temperature or to preserve heat for pipeline Water drains slowly from outfall during water changing Injection port is not open Open the injection port  

Industry Water Chiller >>

$435.00 - 473.00/set

Ships to United States

Details >>

S&A 5200TH Industrial Water Chiller for 130W CO2 Engraver or CNC Spindle Water Cooling, AC 1P 220V 50Hz
10%

S&A 5200TH Industrial Water Chiller for 130W CO2 Engraver or CNC Spindle Water Cooling, AC 1P 220V 50Hz

Item Code: CW-5200THTY

S&A 5200TH Industrial Water Chiller for 130W CO2 Engraver or CNC Spindle Water Cooling, AC 1P 220V 50Hz CAUTIONS We are authorized as "S&A" brand name product agent. All of S&A water chillers are certified with design patent. Counterfeiting is not allowed,  Please recognize S&A logo when you purchase S&A water chillers. Description CW-5200TH industrial water chillers have been popular for over 16 years with the annual output of 30,000 units.It is designed for cooling the one CO2 glass laser tube under 150W of the laser engraving and cutting machine. (Its emitting rate is higher than 60%.)  Cooling capacity is 1400W. Have design patent Certificate, CE and RoHS Certificate. This Water Chiller has been sold largely to Europe, South America, Asia and other markets. Economic cooling equipment, easy to install and operate, compact and easily movable. Features: It is suitable for cooling the laser tube under 150W, and the temperature can be adjusted precisely. You can choose different models according to local voltage and frequency. It can extend the using life of laser tube and ensure the engraving effect better. With completed water flow and over high temperature alarm functions It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices. Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm; This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement. CW-5200 water chiller has unique low flow alarm protection function, which ensures the cooling water cycle working safely. Specific disconnection alarm securing protection. Enclosed water tanks, water used for a long time. Equipped with alarm output port, can quickly protect sensitive components. High cost performance, low failure rate. Multiple power specifications; CE approval; REACH approval; RoHS approval. SPECIFICATION Model CW-5200THTY Voltage AC 1P 220-240V Frequency 50/60Hz Current 0. 5~4.8A Machine power 0.62/0.74kW Compressor power 0.49/0.61kW, 0.65/0.81HP Nominal cooling capacity 4879Btu/h 1.43kW 1229Kcal/h Refrigerant charge 370g Pump power 0.05kW Pump pressure 1.2bar Pump flow 13L/min N.W 25Kgs(55lb) G.W 28Kgs(61.7lb) Refrigerant R-134a Precision ±0.3℃ Reducer Capillary Protection Overcurrent protection for compressor, flow alarm, over temperature alarm Tank capacity 6 L Inlet and outlet 10mm Fast connector   Dimension 580mm x 290mm x 470mm (22.8" x 11.4" x 18.5") Package dimension 650mm x 360mm x 510mm (25.6" x 14.2" x 20") CONTOUR AND PARTS INTRODUCTION   User-friendly control panel The temperature controller offers high precision temperature control of ±0.3°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.     Ease of moving and water filling The firm handle can help move the water chillers easily.     Inlet and outlet connector equipped Multiple alarm protection. The laser will stop working once it receives alarm signal from the water chiller for protection purpose.     Easy-to-read water level indicator The water level indicator has 3 color areas - yellow, green and red. Yellow area - high water level. Green area - normal water level. Red area - low water level.   Dust-proof filter Integrated with the grill of the side panels, easy mounting and removal.   Temperature controller panel description: The new T503 intelligent temperature controller does not need to adjust the controlling parameters under normal circumstance. It will self-adjust controlling parameters according to room temperature for meeting equipment cooling requirements.  User also can adjust the water temperature as needed. Temperature controller panel description: Indicators D1, D2 (as shown) of thermostat working state  D1 ON: thermostat works in intelligent control mode; D1 OFF: thermostat works in temperature control mode; D1 FLASHES: thermostat works in parameters setting mode or displays value of room temperature; D2 ON: chiller works in refrigerating state; D2 OFF: chiller works in the insulation working state;  D2 FLASHES: chiller works in the energy-saving state; Press ▼ button will show the room temperature, 6 seconds later to display the restore defaults.  (Meanwhile, D1 is flashing, displaying room temperature.) ▲▼ keys are for adjusting the display status of the controller, parameters selection and adjustment. RST key: enter key. SET key: function setting key. Alarm function (1) Alarm Display: When alarm occurs, the error code and the temperature will be alternately displayed. (2) To suspend the alarm: In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated. In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000/5200series chillers possesses an unique low flow alarm protection. Ventilation Distance Application Chiller CW-5200 for 150W metal laser cutting machine Water chiller CW-5200 for acrylic co2 laser cutting machine Industrial chiller CW-5200 for laser cutter Air cooled chiller CW-5200 for co2 laser cutting & engraving machine Water cooled chiller CW-5200 for uv laser marking machine CW-5200 chiller for 8w-15w uv laser machine Refrigeration water chiller CW-5200 for laser marking machine Compressor water chiller CW-5200 for UV curing system printer Industrial water chiller CW-5200 for laser marker Certificate Warehouse Test System Installation Open the package to check if the machine is intact and all the necessary accessories are completed.   Open the injection port to feed cooling water. (Do not let the water spill over!)   Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of cooling water additive (anti-corrosion water aqua). Working in cold north area, it’s better to use noncorrosive antifreeze fluid. According to system conditions, please connect the water inlet and outlet pipe well.   Plug in power, turn on the power switch. (Do not start up without water in the water tank!)   (1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal. (2) After the first boot, you must immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set value, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start over the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently. Check the water level in the water tank.   The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage. Adjust parameters of temperature controller.   CW-5000/5200 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to page 15, “Operating status and parameters adjustment.” Cautions Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded!   Please make sure there is stable and normal voltage for the working chiller!   As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 210 ~ 240V (110V model is of 100 ~120V). If you do need a wider operating voltage range, customization is available for us. Unmatched power frequency can cause the chiller damage!   Please choose model of 50Hz or 60Hz according to actual circumstance. To protect the pump, it’s strictly forbidden to run the chiller without water in the storage water tank!   The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited! Please be sure that the air inlet and air outlet are in good ventilation!   There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet. The filter screen must be regularly cleaned!   It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller. Please pay attention to the effect of the condensate water!   With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm. Professional use only!   The appliance is not to be used by children or persons with reduced physical,sensory or mental capabilities, or lack of experience and knowledge,unless they have been given supervision or instruction,children being supervised not to play with the appliance! Troubleshooting Failure Failure Cause Approach Machine turned on but unelectrified Power cord is not plugged in place Check and ensure the power interface and the power plug is plugged in place and in good contact. Fuse burnt-out Pull out the fuse box from the power supply interface of the chiller, check the fuse, replace with spare fuse if necessary and check whether the power supply voltage is stable; Check and ensure the power interface and the power plug is plugged in place and in good contact. Flow Alarm (panel red light is on)use a water pipe directly connect to the water outlet and inlet but still without water flowing Water level in the storage water tank is too low Check the water level gauge display, add water until the level shown in the green area; And check whether water circulation pipe leaks. Flow Alarm occurs while running with other equipment (panel red light is on),but there is water flowing and no alarm when use a water pipe directly connected to the chiller water outlet and inlet. Water circulation pipes are blocked or a pipe bending deformation. Check water circulation pipe Ultra-high temperature alarm Blocked dust gauze, bad thermolysis Unpick and wash the dust gauze regularly Poor ventilation for air outlet and inlet To ensure a smooth ventilation for air outlet and inlet Voltage is extremely low or astable To improve the power supply circuit or use a voltage regulator Improper parameter settings on thermostat To reset controlling parameters or restore factory settings Switch the power frequently To ensure there is sufficient time for refrigeration (more than 5 minuets) Excessive heat load Reduce the heat load or use other model with larger cooling capacity Alarm for ultra-high room temperature The working ambient temperature is too high for the chiller To improve the ventilation to guarantee that the machine is running under 40℃. Serious problem of condensate water Water temperature is much lower than ambient temperature, with high humidity Increase water temperature or to preserve heat for pipeline Water drains slowly from outfall during water changing Injection port is not open Open the injection port     

Industry Water Chiller >>

$491.00 - 534.00/set
$441.00 - 480.00/set

Ships to United States

Details >>

Generic Epson Stylus Pro 7600 Encoder Strip-1232420

Generic Epson Stylus Pro 7600 Encoder Strip-1232420

Item Code: ACC-EPS-027

Generic Epson Stylus Pro 7600 Encoder Strip-1232420 Printer Compatibility: Epson Stylus Pro 7600  Manufacturer: Ving Parts This one can replace the original ones(part no:1232420).

Printer Spare Parts >>

$45.57 - 50.08/pc

Ships to United States

Details >>

Original Epson Stylus Photo 4880 CR Scale - 1518670

Original Epson Stylus Photo 4880 CR Scale - 1518670

Item Code: ACC-EPS-156

Original Epson Stylus Photo 4880 CR Scale - 1518670 Printer Compatibility: Epson Stylus Pro4000 / 4400 / 4450 / 4880 / 4800 Gross Weight: 37g Packing Size: 90mm*90mm*40mm Manufacture: Epson    

Printer Spare Parts >>

$13.23 - 15.03/pc

Ships to United States

Details >>

Epson Stylus Photo R2400 CR Scale

Epson Stylus Photo R2400 CR Scale

Item Code: ACC-EPS-051

Epson Stylus Photo R2400 CR Scale Printer Compatibility: Epson Stylus Photo R1390 / R1800 / R2400 / R1900 / R2000 / ME1100 / C1100 / R1430 / R3000 / R1410 Manufacture: Epson Quality Report:    

Printer Spare Parts >>

$5.88 - 6.68/pc

Ships to United States

Details >>

Generic Roland Encoder Strip for SJ-540 / SJ-740 / FJ-540 / FJ-740 - Length 2.7m,width 1.5cm;180DPI - 22665276

Generic Roland Encoder Strip for SJ-540 / SJ-740 / FJ-540 / FJ-740 - Length 2.7m,width 1.5cm;180DPI - 22665276

Item Code: ACC-ROL-038-R

Roland Encoder Strip for SJ-540 / SJ-740 / FJ-540 / FJ-740 - 2.6m 180DPI-22665276 Printer Compatibility: Roland FJ-500 / FJ-600 / FJ-540 / FJ-740 / SJ-540 / SJ-740 / SJ-745 EX / CJ-400 / CJ-500 / CJ-600 / RS-640 / VP-540 / VP-300 / SP-540 / SP-300 / SP-540V / XJ-740 / XJ-640 / XJ-540 / SC-500

Printer Spare Parts >>

$7.65 - 9.68/pc

Ships to United States

Details >>

Galaxy Printer UD-181LA / UD-1812LA / UD-1812LC / UD-2512LC / UD-3212LC L4500mm x W15mm 180LPI Encoder Strip

Galaxy Printer UD-181LA / UD-1812LA / UD-1812LC / UD-2512LC / UD-3212LC L4500mm x W15mm 180LPI Encoder Strip

Item Code: ACC-LFP-146

Galaxy Printer UD-181LA / UD-1812LA / UD-1812LC / UD-2512LC / UD-3212LC L4500mm x W15mm 180LPI Encoder Strip Printer Compatibility: Galaxy UD-181LA / UD-1812LA / UD-211LA / UD-251LA / UD-2112LA / UD-2512LA / UD-161LC / UD-1612LC / UD-181LB / UD-1812LB / UD-211LC / UD-2112LC / UD-251LC / UD-2512LC

Printer Spare Parts >>

$9.98 - 10.85/pc

Ships to United States

Details >>

Solenoid Electromagnetism Valve / Magnetic Valve for Wide Format Printers (DC24V / 8W)

Solenoid Electromagnetism Valve / Magnetic Valve for Wide Format Printers (DC24V / 8W)

Item Code: ACC-LFP-017A

Solenoid Electromagnetism Valve / Magnetic Valve for Wide Format Printers (DC24V / 8W) Features: • Valve Body using high-grade metal materials , long life • Joint using high quality plastic, strong and durable  Printer compatibility: All Wide Format Printers Manufacturer: Ving Parts Net Weight: 56g/pc Packing Size: 110x70x40mm Gross Weight: 70g/pc • Valve Body using high-grade metal materials , long life • Joint using high quality plastic, strong and durable  Quality Report:

Printer Spare Parts >>

$6.91 - 7.51/pc

Ships to United States

Details >>

HP 60" Encoder Strip for DesignJe 5000 / 5500

HP 60" Encoder Strip for DesignJe 5000 / 5500

Item Code: ACC-HP-004-1

HP 60" Encoder Strip for DesignJet 5000 / 5500 Printer Compatibility: HP DesignJet 5000 / HP DesignJet 5500 printer NOVAJET vulnerable part, normal lifespan: 2 years, when performing normal maintenance. Manufacture: HP  

Printer Spare Parts >>

$117.53 - 133.56/pc

Ships to United States

Details >>

Generic Mutoh RJ-8000 180DPI 87" Encoder Strip, 5000mm Long, 13mm Wide

Generic Mutoh RJ-8000 180DPI 87" Encoder Strip, 5000mm Long, 13mm Wide

Item Code: ACC-WT-046

Generic Mutoh RJ-8000 180DPI 87" Encoder Strip, 5000mm Long, 13mm Wide Printer Compatibility: Mutoh RJ-8000 Manufacturer: Ving Parts      

Printer Spare Parts >>

$13.19 - 16.69/pc

Ships to United States

Details >>

HP Encoder Strip 42" for DesignJet 5000 / 5500

HP Encoder Strip 42" for DesignJet 5000 / 5500

Item Code: ACC-HP-004

HP 42" Encoder Strip for DesignJet 5000 / 5500 Printer Compatibility: HP DesignJet 5000 / HP DesignJet 5500 printer Manufacture: Ving Parts

Printer Spare Parts >>

$44.07 - 50.08/pc

Ships to United States

Details >>

Generic Mutoh RJ-8000 / VJ-1604 Encoder Strip;2180mm x 13mm,180DPI

Generic Mutoh RJ-8000 / VJ-1604 Encoder Strip;2180mm x 13mm,180DPI

Item Code: ACC-WT-029

Generic Mutoh RJ-8000 / VJ-1604 Encoder Strip;2180mm x 13mm,180DPI Printer Compatibility: Mutoh RJ-8000 / RJ-8100 / VJ-1604 / VJ-1618 / VJ-1204 / VJ-1304 /  VJ-1324 / RJ-900C / Mutoh VJ-1614A / Mutoh Rockhopper II / Rockhopper III / Mutoh Falcon II / Mutoh VJ-1624 Manufacturer: Ving Parts

Printer Spare Parts >>

$9.24 - 11.69/pc

Ships to United States

Details >>

10 Colors Car Accessory Car Tyre Decorate Strips

10 Colors Car Accessory Car Tyre Decorate Strips

Item Code: SIC-POP-01

 Introduction: 1.Length is 26ft (8 meters), and it is suitable for all regular tyres range from 16inch to 28inch which is enough for 4 pieces. 2.10 colors  for your selection, blue,yellow,rose,white,purple,green,orange,grey,black. 3.Ahersion promotor & doubled sided tape is free with the stripes. Features: 1.Defend the tyre from outside damage effectual. 2.It is made of PVC material, which is enviroment-friendly and no harm. 2.Heat/cool resistant & anti oxidation 3.Soft & flexible with good durable Details: Install Instruction: Application:  

Ebay Combination Products Only >>

$3.01 - 3.34/pc

Ships to United States

Details >>

V Shaped LED Tube T8 Integrated Fixture Light 8FT 65W 85-265V Dual Row LED Bulb

V Shaped LED Tube T8 Integrated Fixture Light 8FT 65W 85-265V Dual Row LED Bulb

Item Code: LED-AR-T8-Y2400-V-A1

Features: 1.Save electricity bill, save energy and reduce maintenance costs. 18W LED Tube Light replace 50W fluorescent tube light. 2. No ballast and starter required. No more buzzing sound. 3. Easy Installation. 4. Eco-Friendly. No lead or mercury. 5.Rated at 50,000 hour life span. 6. 2 Year

LED Tube Light >>

$16.27 - 19.37/pc

Ships to United States

Details >>

Generic Mimaki JV3 / JV33 Linear Encoder Scale;180DPI,3.2m - E300353

Generic Mimaki JV3 / JV33 Linear Encoder Scale;180DPI,3.2m - E300353

Item Code: ACC-MIM-041-M

Mimaki Linear Encoder Scale for JV3-250---3.2m 180DPI Printer Compatibility: Mimaki CJV30-100 / CJV30-100BS / CJV30-130 / CJV30-130BS / CJV30-160 / CJV30-160BS / CJV30-60 / CJV30-60BS / JV2-130 / JV2-180 / JV2-90 / JV22-130 / JV22-160 / JV3-130S / JV3-130SL / JV3-130SP II / JV3-160S / JV3-160SP / JV3-250SP / JV3-75SP II / JV33-130 / JV33-130BS / JV33-160 / JV33-160BS / JV4-130 / JV4-160 / JV4-180 / JV5-130S / JV5-160S / PV-130 / PV-90 / TS3-1600 / TS5-1600AMF Manufacturer: Ving Parts  

Printer Spare Parts >>

$12.53 - 15.86/pc

Ships to United States

Details >>

Subscribe to our special offers:
Follow us: 'like' us on Facebook 'Fallow us on Youtube