S&A 3000DG Thermolysis Industrial Water Chiller for CO2 Glass Tube of Engraving Machine, AC 1P 110V, 60Hz
Item Code: CW-3000DGTY
forced air - cooled radiator; CW-3000 Laser Water Chiller is suitable for small water cooling device; Provide stable working conditions for laser devices; High heat dissipating capacity and not easy to be blocked. SPECIFICATION Model CW-3000DGTY Voltage AC 1P 110V Frequency 50/60Hz Current
Ships to United States
S&A CW-5000TG Industrial Water Chiller for Single 80W or 100W Engraving Machine, 6L Tank capacity, 750W Cooling Capacity, AC 1P 220-240V, 50Hz
Item Code: CW-5000TGTY
filled correctly according to the Filling Requirements paper put in the accessories box before running the chiller. ONTOUR AND PARTS INTRODUCTION Independent production of sheet metal User-friendly control panel The temperature controller offers high precision temperature control of ±
Ships to United States
S&A CW-5000DG Industrial Water Chiller for Single 80W or 100W Engraving Machine, 6L Tank capacity, 750W Cooling Capacity, AC 1P 110V, 60Hz
Item Code: CW-5000DGTY
It is designed for cooling the one CO2 glass laser tube under 150W of the laser engraving and cutting machine. (Its emitting rate is higher than 60 %.) Cooling capacity is 800W. Have design patent Certificate, CE and RoHS Certificate. This water chiller has been sold largely to Europe, South America, Asia and other markets. Economic cooling equipment, easy to install and operate, compact and easily movable. Features: • It is suitable for cooling the laser tube under 150W, and the temperature can be adjusted precisely. • You can choose different models according to local voltage and frequency. • It can extend the using life of laser tube and ensure the engraving effect better. • With completed water flow and over high temperature alarm functions • It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices. • Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm; • This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement. • CW-5000 water chiller has unique low flow alarm protection function, which ensures the cooling water cycle working safely. • Specific disconnection alarm securing protection. • Enclosed water tanks, water used for a long time. • Equipped with alarm output port, can quickly protect sensitive components. • High cost performance, low failure rate. • Multiple power specifications; CE approval; RoHS approval. Tips: Make sure the refrigerant is filled before running the chiller. Refrigerant is forbidden by express company, so we could not put it into the package.You can buy it locally and fill it out. If the compressor of this chiller has not been filled with refrigerant. Please make sure it has been filled correctly according to the Filling Requirements paper put in the accessories box before running the chiller. User-friendly control panel The temperature controller offers high precision temperature control of ±0.3°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode. Easy-to-read water level indicator The water level indicator has 3 color areas - yellow, green and red. Yellow area - high water level. Green area - normal water level. Red area - low water level. Dust-proof filter Integrated with the grill of the side panels, easy mounting and removal. Ease of moving and water filling The firm handle can help move the water chillers easily. Ventilation Distance Alarm Function’s Description: Flow alarm and output ports: In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection. The cooling water circulation loop alarm causes and the work of the state table Normal Flow Indicator Flow Alarm Indicator Buzzer Output Ports Hi, H2 Output Ports H1, H3 Circulating pump works properly ON OFF NOT RING DISCONNECTION BREAKOVER Blocked cooling water circulation loop OFF ON RING BREAKOVER DISCONNECTION Alarm of water shortage OFF ON RING BREAKOVER DISCONNECTION Faulted circulating pump OFF ON RING BREAKOVER DISCONNECTION Power interruption / / / BREAKOVER DISCONNECTION Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V. Fill the water tank with purified water. Connect the water inlet of the water tank to the water outlet of the laser machine and connect the water outlet of the water tank to the water inlet of the laser machine. Connect the signal line of the water tank with that of the laser machine. Please see pictures below. Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps. A.Open the package to check if the machine is intact and all the necessary accessories are completed. B.Open the injection port to feed cooling water. Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid. C.According to system conditions, please connect the water inlet and outlet pipe well. D.Plug in power, turn on the power switch. (Do not start up without water in the water tank!) (1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal. (2) After the first boot, you must immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently. E.Check the water level in the water tank. The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage. F.Adjust parameters of temperature controller. CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.” Maintenance Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation. You can use non – corrosive antifreeze if you are in the northern cold regions. Cautions 1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps). 2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us. 3. To protect the pump, it’s strictly forbidden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited! 4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet. 5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller. 6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm. Application: CW5000-water-chiller-cool-for-Picosecond-Lasers CW5000-water-chiller-cool-for-UV-laser-marking-machine CW5000-water-chiller-cool-for-Uv-solid-laser CW5000-water-chiller-for-cooling-700W1500W-UV-light-source CW5000-water-chiller-for-cooling-UV-LED-source Industrial-chiller-CW-5000-for-HF-welding-machine Quality Report:
Ships to United States
16" x 16" (420mm x 420mm) Metal Mold CNC Router
Item Code: CNCR-MEII-4242
comes with a German ball screw, high speed double CPU-CNC control system, SaiO2 controller, microstep driver and a 1.5kw water cooled spindle. . Equipped with Type3 engraving software. The CNC mould engraver is compatible with different CAD/CAM software, such as Artcam, Casmate, Proe, UG, Artgrave
Ships to United States
S&A 5200TH Industrial Water Chiller for 130W CO2 Engraver or CNC Spindle Water Cooling, AC 1P 220V 50Hz
Item Code: CW-5200THTY
S&A 5200TH Industrial Water Chiller for 130W CO2 Engraver or CNC Spindle Water Cooling, AC 1P 220V 50Hz CAUTIONS We are authorized as "S&A" brand name product agent. All of S&A water chillers are certified with design patent. Counterfeiting is not allowed, Please
Ships to United States
CALCA 500ml Blank Aluminum Sports Bottle for Sublimation Printing Dia 2.83"
Item Code: CS-LH-02
Specifications: • Capacity: 500ml • Material: Aluminum • Color: White/Silver • Quantity: 50pcs/carton • Suitable for thermal transfer personal photo, picture, company logo etc. • Each bottle comes in one individual white box. Details: Application:
Ships to United States
L-Shaped Desk Label 3.3" x 2.2" (83 x 55mm)
Item Code: SIC-LQ-L6121
Description: The L-shaped Desk Label is widely used at kinds of desktop displaying because of its simple style, convenient usage and wonderful display effect. It is a kind of high-grade product that is adopting good material and mature technology to produce excellent and nice labels. This product has various sizes for applying to kinds of displaying requirements, such as names, code guidelines, single-page descriptions, announcements, advertisings, etc. Application: It's widely used for names, code guidelines, single-page descriptions, announcements, advertisings, etc.
Ships to United States
Original Epson Stylus Pro 4880 Mainboard Brand (Second Hand)
Item Code: ACC-EPS-022
Epson Stylus Pro 4880 Mainboard-2131668 Printer Compatibility: Epson Stylus Pro 4880 Gross Weight: 518g Packing Size: 320mm*190mm*60mm Manufacture: Epson
Ships to United States
Epson Stylus Pro 4880 Cutter
Item Code: ACC-EPS-019
Epson Stylus Pro 4880 Cutter Printer Compatibility: Epson Stylus Pro 4000 / Epson Stylus Pro 4400 / Epson Stylus Pro 4450 / Epson Stylus Pro 4880 / Epson Stylus Pro 7400 / Epson Stylus Pro 7450 / Epson Stylus Pro 7600 / Epson Stylus Pro 7880 / Epson Stylus Pro 9400 / Epson Stylus Pro 9450 / Epson Stylus Pro 9600 / Epson Stylus Pro 9880 / Epson Stylus Pro 9800 / Epson Stylus Pro 4800 Net Weight: 4g Product Size: 50mm*25mm*25mm Manufacturer: Epson
Ships to United States
Epson Stylus Pro 4880 CR Motor-2100038
Item Code: ACC-EPS-075
Epson Stylus Pro 4880 CR Motor-2100038 Printer Compatibility: Epson Stylus Pro4000 / 4400 / 4450 / 4880 / 4800 Gross Weight: 265g Packing Size: 75mm*95mm*65mm Manufacture: Epson Part number: 2100038
Ships to United States
Epson Stylus Pro 4880 / 4800 Cap Capping top
Item Code: ACC-EPS-109
Epson Stylus Pro 4880/ 4800 Cap Capping top Printer compatibility: Epson Stylus Pro 4880 / 4800 Manufacturer: Ving Parts Product Size: 50mm*40mm*30mm Net Weight: 7g
Ships to United States
Original Epson Stylus Photo 4880 CR Scale - 1518670
Item Code: ACC-EPS-156
Original Epson Stylus Photo 4880 CR Scale - 1518670 Printer Compatibility: Epson Stylus Pro4000 / 4400 / 4450 / 4880 / 4800 Gross Weight: 37g Packing Size: 90mm*90mm*40mm Manufacture: Epson
Ships to United States
Original Epson Stylus Pro 4880 T Shape Board - 2060507
Item Code: ACC-EPS-106
Original Epson Stylus Pro 4880 T Shape Board - 2060507 Printer Compatibility: Epson Stylus Pro 4000 / Epson Stylus Pro 4400 / Epson Stylus Pro 4450 / Epson Stylus Pro 4880 / Epson Stylus Pro 7400 / Epson Stylus Pro 7450 / Epson Stylus Pro 7600 / Epson Stylus Pro 7880 / Epson Stylus Pro 9400 / Epson Stylus Pro 9450 / Epson Stylus Pro 9600 / Epson Stylus Pro9880 Manufacturer: Epson
Ships to United States
Epson Stylus Pro 4880 Power Board Brand New-2091981
Item Code: ACC-EPS-118
Epson Stylus Pro 4880 Power Board-2091981 Printer Compatibility: Epson Stylus Pro 4880 Gross Weight: 665g Packing Size: 215mm*185mm*120mm Manufacture: Epson
Ships to United States
Epson Stylus Pro 4880 PF Motor-2091572
Item Code: ACC-EPS-072
Epson Stylus Pro 4880 PF Motor-2091572 Printer Compatibility: Epson Stylus Pro 4000 / 4400 / 4450 / 4880 / 4800 Gross Weight: 262g Packing Size: 70mm*95mm*60mm Manufacture: Epson Part number: 2091572
Ships to United States
Epson Stylus Pro 4000 / 4400 / 4450 / 4880 / 4800 CR Sensor--1476585
Item Code: ACC-EPS-084
Epson Stylus Pro 4000 / 4400 / 4450 / 4880 / 4800 CR Sensor--1476585 Printer Compatibility: Epson Stylus Pro 4000 / Epson Stylus Pro 4400 / Epson Stylus Pro 4450 / Epson Stylus Pro 4880 / Epson Stylus Pro 4800 Part number: 1476585 Manufacture: Epson
Ships to United States